Versions Compared
Key
- This line was added.
- This line was removed.
- Formatting was changed.
Warning | ||
---|---|---|
| ||
You must not use the DFS that is included in the 4.7.0 release of the Digizuite™ DAM Center. |
Info | ||
---|---|---|
| ||
The way to change your password has changedThe way you change password inside the DC has changed a bit. How to access itGo to System tools → Users and groups → Users and choose any user. Then open the editor at the right. In the bottom of that page, you will see a button that you have to press to change passwords. How to configure itThe password input field has been removed. In order to change password, you have to click the button Change password. If the user who is logged in has the role Editor_SystemTools_UserManager_User, he or she will be able to change any users user's password without entering the existing password first. |
Info | ||
---|---|---|
| ||
UI for old profiles and destinations is removedThe functionality stays but the UI is removed. Guide and further explanation can be found here:How to move old profiles and destinations configuration to new |
Info | ||
---|---|---|
| ||
The installer will now install most external requirementsBy using the Digizuite™ DAM Center installer, most of the old requirements that you had to manually configure (IIS roles and features - and programs) are not needed anymore. The only things you now need that are hard requirements when installing (NOT updating) are:
How to access itYou do not have to do anything more than the four steps above, for an installation to go through. Of course there are many other things that should be done, for an installation to function properly, but a lot of the manual labor that you'd have to do each time you should install has now been included in the installation program. How it worksIt makes certain that the system has all the required prerequisites in place when installing. It'll configure and install the required things in order to make certain that the DC works. How to configure itYou do not have to do any configuration |
Info | ||
---|---|---|
| ||
New Search Editor (Search2)Search2 has gotten a new, more user friendly UI. The new Search Editor is a replacement for the XML text area, which was previously used to edit and/or create searches. The XML definition of a search has been completely black boxed, in that a user no longer sees the XML. Instead the XML is parsed and displayed in a more user friendly manner. The "user friendly" part of the new UI is that several choices are made for the user, for example the order of filters, which is now programmatically calculated; it is impossible to make mistakes with regard to "valueHandler"-"renderType" combinations, etc. The only times where a user is forced to input text is for a filter/value field's ID and any "predetermined values". How to access it1. Go to DAM Center. 2. Expand the System Tools tab in the left navigation bar. 3. Expand Config Manager. 4. Select the desired product version. 5. Click the Searches tab. 6. Select a search. How it worksParses a given search into a UI, which helps the user perform edits to the search. How to configure itSimply works Out Of the Box. |
Info | ||
---|---|---|
| ||
New Search documentation (Search2)The new Search Editor comes with updated documentation, which guides the user through the use of the new Search Editor as well as defining various terms such as "valueHandler" and all of its allowed values. How to access it1. Go to the confluence site 2. Go to the Documentation space 3. Expand Digizuite™ DAM Center 4. Expand Digizuite™ DAM Center v4.7.0 5. Expand Configuration Guides - Digizuite™ DAM Center v4.7.0 6. Click on Draft - Search Editor - DAM v4.7.0. The pages contained within this section is the new documentation How it worksThe documentation guides the user through the new Search Editor. It also defines terms such as "valueHandler" and "renderType" and gives thorough explanations of all available values and the impact of choosing the various values. How to configure itNo configuration is needed. |
Info | ||
---|---|---|
| ||
Better out of the box experience for new installationsWhen you install (note update) a new version of the DAM Center, it'll now include our best practices setup, instead of the old legacy standard configuration. In the new version of DC, you'll have the following new functions (Including; but not limited to):
How to access itThe OOBE (Out of the Box Experience) information pamphlet contains all the information required for having an overview about all the new features and functionalities. |
Info | ||||||
---|---|---|---|---|---|---|
| ||||||
Manage Digizuite™ Office Connector clientsYou can view office clients that has connected through office connector plugin and from the UI, you can delete clients. This feature is useful when the office license is limited and not unlimited users. How to access itSystem tools → License → Digizuite™ Office Connector clients and click the icon at the right side. How it worksPlease see this video on how it works:
How to configure itIt simply works out of the box. |
Info | ||
---|---|---|
| ||
The ability to en- and disable the ability to bypass the "required fields" check by multi-selectingUp until now, there has not been a check for determining whether there were required fields while uploading or editing multiple assets' metadata. This meant, that by simply selecting multiple assets, you'd be able to circumvent the check that made certain that some fields would already be filled out upon editing and uploading. In this version of the DC there's been added a new config variable: 'VALIDATE_REQUIRED_WHEN_MULTISELECTING'. This has been introduced to enable or disable the previously mentioned check. It will be enabled by default after an update to DC 4.7.0. How to access itWhen VALIDATE_REQUIRED_WHEN_MULTISELECTING is set to "1" - and more than one asset is selected while editing metadata - the required check will be performed as it normally would when editing one asset. How it worksIf no input has been given, the UI will show both an asterisk and a red border around the input field. See the image below. If the field is valid, it'll look like this: How to configure itGo to System tools → Digizuite configuration and find VALIDATE_REQUIRED_WHEN_MULTISELECTING in the list. Set it to 1 to enable the feature and 0 to disable it. When disabling the feature functionality will be as pre-4.7.0, meaning that the required fields yet again will not be required when multi-selecting. Ps. It currently cannot be searched for. Please go to page 19, to find the variable - the list is sorted alphabetically. |
Table of Contents |
---|